Energy meter construction pdf

If a meter is used in combination with a current transformer. Utilities are one of the electrical departments, which install these instruments at every place like homes, industries, organizations, commercial buildings to charge for the electricity consumption by loads such as lights, fans, refrigerator, and other home appliances. To study the construction and working of single phase energy meter and to find out energy consumed in 30 minutes. Working principle and construction of energy meter video lecture of measurement of capacitance chapter in subject electronic. Wireless automation in the generation, transmission and distribution of electricity and billing has come of age. The circuit shown in figure1 is the circuit of energy metering. Energy meter working principle and construction electronic. Electrical energy meters principles and applications. Energy meter or watthour meter is an electrical instrument that measures the amount of electrical energy used by the consumers. Our xcel energy standards of installation and use manual pdf is your best resource to find and share information with all trades supporting your project. Energy meters are the basic part to measure the power consumption. Jul 25, 2018 energy meters are the basic part to measure the power consumption. Xcel energy is dedicated to providing safe, economical, and reliable service to our customers.

What is the solution for the drawbacks of commonly used energy meters. Pdf this paper presents design and construction of a threephase smart energy meter. Study of single phase induction type energy meter or watt. The energy is the total power consumed and utilised by the load at a particular interval of time.

Guidance on development of energy projects, november 3, 2016 pdf, 1. Traditional metering methods for retrieving the energy data of consumers is not convenient. It works on the basic principle of bernoullis equation. For underground service, the customer must perform all the civil work for the austin energy facilities installed on the customers property. Use the following specifications, codes, and technical manuals to help design your electric facility. Mar 28, 2017 induction type single phase energy meter.

It is used everywhere, no matter how big or small consumption it is. Depending upon the result, the microcontroller will activate the buzzer. The principle of working and construction of induction type meter is very simple and easy to understand thats why these are widely used in measuring energy in domestic as well as the industrial world. Wireless energy meter is a system developed to serve as a basic singlephase energy meter with advanced functionalities such as peak hour setting, peak load setting wireless reading transmission. Installation manual three phase energy meter inogate. Meter installation from padmount transformer w vt pack 480v figure 15. Design and implementation of a singlephase energy meter with. Energy meter circuit detailed project with source code.

An electricity meter, electric meter, electrical meter, or energy meter is a device that measures the amount of electric energy consumed by a residence, a business, or an electrically powered device. The internal construction of the meter is not described here, as meter protected by manufacturer seal. Energy meter is an instrument which measures electrical energy. Mckinney, tx 75069 ph 9725477400 fax 9725472605 hours monday friday 8 a. You can recharge the electricity balance through this system, just by sending a sms. Handbook on electricity meters asiapacific economic.

Applicaton for electric meter installation questions or comments. It is used in domestic and industrial ac circuit for measuring the power consumption. When the standards are updated, the latest version will be posted here. Its important you obtain the standards from this website, so you are using the latest version. Overview of single phase induction type energy meter. Presented here is a simple energy meter using analog devices ade7757 chip for singlephase, 2wire phase and neutral systems used in households. This design implements a highaccuracy singlephase embedded energy measurement application using msp430afe253. In simple language, this is defined as the sum of pressure energy, kinetic energy per unit volume and potential energy per unit volume equal in the same. Includes clearance and access issues, meter placement and meter connections. Watthour meter maintenance and testing, january 1992. The information found on this page outlines the minimum requirements necessary to connect to. Building inspection forms mckinney, tx official website.

In all induction meters, we have two fluxes which are produced by two different alternating currents on a metallic disc. This type of energy meter is simple in construction and the accuracy is somewhat less due to creeping and other external fields. Those consumers which consume large energy needs better technology to manage their energy consumption and need more data to improve their services. Download service and meter charges pdf austin energy affordable housing policy. In this project we are building a automated system by using arduino and gsm module. Once youve completed the inquiry form, you may submit it by email or mail. Learn how were delivering energy for a brighter future.

American electric power company meter and service guide 4 figure 14. The customer will be responsible for labeling the house piping as stipulated in section 401. The michels corporation construction foreman will need access to centerpoint energys natural gas meter inside your house to move the meter outside and relight your natural gas appliance pilot lights after the meter is relocated. Department of defense utilities meter policy, april 16, 20 pdf, 596kb.

The electric service standards manual is available to reference as you are planning your electric service construction and meter installation. The following information may be needed in order for your dominion energy representative to begin working on a project plan and design package. The energy meter reading is compared with the smart card information by the microcontroller. Energy meter calibration is in billing units which are rated in kilowatthour kwh. Instrument transformer rated meter sockets and ct metering cabinet list approved list for use in tampa electric service areas only. Work with your assigned xcel energy representative to find out how this information applies to your project. We are proud to work with homebuilders throughout our service territories to bring economic growth and opportunity to the people and communities we serve. This will be converted into corresponding measurements in the display section. A single phase induction type energy meter consists of driving system, moving system, braking system and registering system. Electric utilities use electric meters installed at customers premises for billing and monitoring purposes. Smart card, which is the switch, gives information about the limitation of units. Induction type energy meter used invariably to measure the energy consumed in any a.

Here we discuss the construction and working principle of induction type energy meter. But these are now being gradually replaced by electronic digital energy meters. Meter installation from padmount transformer usi ng bushing type cts figure 14b. The meter which is used for measuring the energy utilises by the electric load is known as the energy meter. To understand the basic construction and different components of a single phase induction type energy meter. Venturi meter is a device or component which is used for measuring the rate of flow of liquid through pipes. The information is provided in printerfriendly adobe acrobat pdf. The conventional mechanical energy meter is based on the phenomenon of magnetic induction. Prepaid electricity energy meter is a good concept in which you can recharge its balance, like we do in our mobile phones. This will reduce the risk of project delays or expensive changes during. Other guides, specifications, standards, and code austin energy. Based on the flow of current, the ferriwheel rotates which makes rotation of other wheels.

Alliant energys electric and gas service manuals supply essential information to customers, employees, architects, engineers, contractors, inspectors, and others concerned with the planning and construction of electric and gas service installations in our utility service areas. The basic principle of induction type energy meter is electromagnetic induction. To expedite service connections and treat each of our customers equally and fairly, we have developed installation standards for gas and electric services. A foremost problem with these types of energy meters is their proneness to tampering, which necessitates an electrical energy monitoring system.

Electromechanical energy meters have been the standard for metering the electricity since billing began. In every residence, malls, industry, everywhere energy meters are used to measure the electrical energy consumed. What are the advantages and disadvantages of usual energy meters. It consists of two electromagnets, called shunt magnet and series magnet, of laminated construction. Commonly used requirements have been included below for easy access. A coil having large number of turns of fine wire is wound on. One single phase energy meter, one single phase load, stop watch and connecting wires. All new, relocated or upgraded residential service connections will be installed as underground residential service laterals at the customers expense. This evm has builtin support for measuring ac voltage, current, active power, reactive power, apparent power, frequency, power factor, dc voltage, dc current, and dc active power.